Consumer Unit Replacement with RCBOs and Surge Protection — Woodley
A dual-RCD consumer unit that had been in for around 20 years replaced in Woodley, Stockport. The customer needed surge protection and wanted RCBOs, so the new Live board has an RCBO for each circuit, an SPD and a 100A main switch.
What we did on this Woodley job
The detail behind the project — what the client needed, how we approached it, and what was specified for the future.
A customer in Woodley asked us to replace their consumer unit. It was a dual-RCD style board that had been fitted around 20 years ago. They needed surge protection (an SPD) adding, and they wanted RCBOs on each circuit rather than the dual-RCD arrangement.
We took the old board off the wall, leaving the circuit cables ready for the new one, and fitted a new Live consumer unit in its place. Each circuit now has its own RCBO: the cooker, sockets, outside socket, lighting and central heating are all labelled on the board. Alongside them are an SP140 surge protective device and a 100A main switch.
With RCBOs, each circuit has its own earth-leakage protection, so a fault on one circuit only switches off that circuit. Whatever caused it is easier to find, and the rest of the house stays on. The SPD protects the wiring and anything plugged into it from voltage spikes coming in on the supply.
The finished board carries our inspection labels, showing the date of this inspection and the recommended date of the next one. If your consumer unit is getting on in years, or you'd like surge protection or RCBOs added, we cover Woodley, Bredbury, Romiley and the rest of Stockport. Get in touch for an honest look at what your board needs.