Shower Installation

Electric Shower Installation

Professional electric shower installation with dedicated high-power circuits, correct cable sizing, and full RCD protection. Our qualified electricians ensure your shower is safe, powerful, and compliant with BS 7671 wiring regulations across Manchester.

What Goes Into a Safe Installation

An electric shower draws significant power. Here's how we ensure every installation is safe, compliant, and built to last.

Dedicated Circuit

Every electric shower gets its own radial circuit running directly from your consumer unit, with the correct cable size calculated for your specific property and shower rating.

RCD Protection

A 30mA Residual Current Device is fitted as standard on every shower circuit, cutting the power in milliseconds if a fault is detected to prevent electric shock.

Correct MCB Selection

We match the Miniature Circuit Breaker to your shower’s kW rating and cable size, ensuring reliable overcurrent protection without nuisance tripping.

Voltage Drop Calculation

We calculate the voltage drop across the full cable run to ensure your shower receives adequate power, especially in larger properties where the consumer unit is far from the bathroom.

Bathroom Zone Compliance

Installation fully complies with BS 7671 bathroom zoning regulations. All connections, isolator switches, and the shower unit itself are positioned within the correct zones.

Full Certification

Every installation comes with an Electrical Installation Certificate, giving you peace of mind and protecting your property’s value.

Frequently Asked Questions

The cable size depends on the shower’s kilowatt (kW) rating and the length of the cable run from the consumer unit. Most 8.5kW showers need a 6mm² twin-and-earth cable on a 40A MCB, while 9.5kW and 10.5kW showers typically require 10mm² cable on a 45A or 50A MCB. We calculate the exact requirements based on your property to ensure safe operation with no voltage drop issues.

Yes. An electric shower must have its own dedicated radial circuit running directly from the consumer unit. It cannot be connected to an existing ring main or shared with other appliances. The circuit must also be protected by a 30mA RCD to prevent electric shock, and a correctly rated MCB to protect against overload.

In most cases, yes. However, the installation must comply with BS 7671 bathroom zoning regulations. The shower unit itself must be suitable for the zone it’s installed in (typically Zone 1 or Zone 2), and the pull-cord isolator switch must be positioned outside the zones or be suitably IP rated. We’ll survey your bathroom to confirm the best and safest location.

A straightforward replacement on an existing circuit typically takes 2 to 3 hours. A new installation requiring a dedicated circuit from the consumer unit usually takes a full day, depending on the cable route and accessibility. We’ll give you an accurate timeframe after surveying your property.

Higher kW ratings deliver hotter water at a stronger flow rate. For most Manchester homes, a 9.5kW or 10.5kW shower offers the best balance of performance and practicality. However, your existing electrical supply and cable capacity may influence the maximum kW rating we can install. We’ll advise you on the best option during our free survey.

Areas We Cover

We provide electric shower installation across Denton, Tameside, Stockport and the wider Greater Manchester area — find your local team below.

Need an Electric Shower Installed?

Whether you’re replacing an old unit or fitting a brand new electric shower, our qualified electricians will ensure it’s installed safely with the correct cable, circuit protection, and full certification.

Call Now Get a Quote